One polyanion + hard carbon system, split into three product lines by capacity, rate capability and cost, covering consumer electronics, traction and storage. Full specifications and selection rationale follow.
AA standard size, 3.0V, 460mAh. A drop-in replacement for equivalent lithium and alkaline cells, pushing the operating temperature floor down another 30 degrees.
| Product model | King-Sodium Series 5 (AA / 14500) |
| Nominal voltage / capacity | 3.0 V / 460 mAh @0.2C |
| Nominal energy | 1.5 Wh |
| Dimensions | φ14.0 × 50.0 mm (AA standard) |
| Weight | ≈ 21 g |
| Charge cut-off voltage | 4.0 V |
| Discharge cut-off voltage | 2.0 V |
| Max continuous discharge current | 2C (920 mA) |
| Peak pulse discharge | 1,000 A (millisecond class) |
| Low-temperature discharge | ≥80% capacity retention at −50°C |
| High-temperature discharge | Operates at +60°C |
| Charge temperature range | −20℃ ~ +55℃ |
| Cycle life | ≥800 cycles @70% retention |
| Self-discharge rate | ≤3% / month @25°C |
| Over-discharge recovery | Charges normally after 0V deep discharge |
| Housing material | Nickel-plated steel / aluminium-laminate optional |
| Safety tests | All 12 passed (nail penetration, crush, thermal box) |
| Certification status | SGS CGE20251100120081 / UN 38.3 / RoHS / REACH |
| MOQ | 5,000 pcs |
| Standard lead time | 7 days in stock / 25 days custom |
Test conditions: 0.5C discharge to 2.0V, with 25°C capacity as the 100% baseline.
Test conditions: 1C charge / 1C discharge, 25°C, 100% DOD.
In conventional lithium cells, over-discharge to 0V dissolves the copper anode current collector and forms dendrites on recharge, causing internal short circuits. King-Sodium Series 5 uses an aluminium collector and a matched system, so it recovers safely after over-discharge. For long-duration low-current standby devices such as locks and smoke detectors, this sharply cuts after-sales write-offs.
For long standby and cold environments, 0V rechargeability removes over-discharge write-offs.
Over 12 years of standby, with self-discharge as low as 3%/month.
Drop-in AA standard size, no lithium or cobalt — cleaner by design.
Reliable discharge outdoors at −40°C, no fire at high temperature.
The φ120 × 420mm large cylindrical format starts at 280Ah and reaches 2,500Ah per cell: fewer case parts, a shorter electron path and a clearer venting direction.
| Series model | 120420 (φ120 × 420 mm) |
| Capacity tiers | 280 / 600 / 1200 / 2500 Ah |
| Nominal voltage | 3.0 V |
| Energy range | 0.84 kWh (280Ah) ~ 7.5 kWh (2,500Ah) |
| Cathode system | Polyanion (phosphate framework) |
| Anode system | Biomass hard carbon |
| Charge cut-off voltage | 4.0 V |
| Discharge cut-off voltage | 1.8 V |
| Max continuous discharge | 1C |
| Peak pulse discharge | 1000 A |
| Operating temperature · discharge | −40℃ ~ +60℃ |
| Operating temperature · charge | −20℃ ~ +55℃ |
| Cycle life | ≥6,000 cycles @80% DOD (storage duty) |
| Thermal runaway onset | ≥325°C (nail penetration) |
| Structural features | Full-tab / bottom collector / axial venting |
| Case material | Aluminium alloy (nickel-plated steel optional) |
| Volumetric utilisation | ≥92% |
| Pack efficiency | ≥88% |
| Capacity consistency | within ±2% |
| Certification status | UL 1973 / UL 9540A / IEC 62619 / UN 38.3 |
Large cylindrical cells are not cost-free: the higher the per-cell capacity, the stricter the demands on BMS sampling accuracy and temperature uniformity; a larger diameter raises the precision required of winding equipment and electrode alignment. King-Sodium has completed full process validation on the 120420 platform and supplies module-level thermal simulation boundary conditions.
Raw materials avoid lithium, cobalt and nickel — elements exposed to geopolitical and price volatility — giving supply-chain stability well above NMC systems.
Polyanion cathodes decompose at a higher temperature than layered oxides; combined with a hard carbon anode, they neither ignite nor explode under nail penetration, with thermal runaway onset ≥325°C.
6,000 cycles @80% DOD means over 8 years of theoretical service at two cycles a day, with a levelised cost below lead-acid and lithium options.
Four system formats span everything from 10kWh residential to 1.7MWh containers, all managed by our in-house EMS with multi-unit parallel operation and cloud-based strategy dispatch.
Containerised utility storage
720V DC side, 2-hour configuration, 20-ft standard sea container. Scalable in parallel to hundred-MWh plants.
C&I storage cabinet
Dual peak-valley arbitrage and demand management, 1–4 cabinets in parallel, integrated with the park EMS.
Residential storage system
Wall-mounted and floor-standing formats, paired with residential PV for self-consumption, peak-valley arbitrage and backup.
Telecom base station backup
A drop-in lead-acid replacement: normal float charge and discharge in outdoor cabinets at −40°C, with over 3× the cycle life.
| Rated DC-side voltage | 720 V |
| Rated capacity per container | 1.7 MWh |
| Rated power | 800 kW |
| Rated charge/discharge duration | 2 h |
| Cell configuration | 120420-600 modular series |
| Cycle life | ≥6,000 cycles @80% DOD |
| System efficiency | ≥92% (incl. PCS and thermal control) |
| Operating temperature | −30℃ ~ +55℃ |
| Thermal management | Liquid cooling + zoned air ducts |
| IP rating | IP54 (IP55 optional) |
| Fire suppression | Pack-level aerosol + cabinet-level perfluorohexanone |
| Communication interface | Modbus TCP / IEC 61850 / CAN |
| EMS functions | Peak-valley strategy / demand control / remote O&M |
| Standard size | 20-ft standard sea container |
| Warranty | System 5 years / cell 8 years (extendable) |
| Capacity per cabinet | 215 kWh |
| Rated power | 100 kW |
| DC voltage range | 600 – 900 V |
| Cell configuration | 120420-280 modular |
| Cycle life | ≥6,000 cycles @80% DOD |
| System efficiency | ≥90% |
| Operating temperature | −20℃ ~ +50℃ |
| Thermal management | Liquid cooling / air conditioning optional |
| IP rating | IP54 (outdoor cabinet) |
| Fire suppression | Pack-level aerosol + smoke detection |
| Parallel capability | 1–4 cabinets in parallel (up to 860 kWh) |
| Communication interface | Modbus TCP / 4G gateway |
| Installation | Floor-standing / outdoor / in-container |
| Typical payback | 4–5 years (Jiangsu–Zhejiang peak-valley spread) |
| Warranty | System 5 years / cell 8 years |
The payback figures above assume a typical Jiangsu–Zhejiang C&I peak-valley spread (about RMB 0.75/kWh), one charge-discharge per day and 330 operating days a year. Actual payback depends on local tariff policy, load profile and grid-connection conditions; King-Sodium can produce a custom calculation for your project.
Locate the recommended product quickly by application, temperature and capacity.
| Applications | Featured products | Selection notes | Maturity |
|---|---|---|---|
| Smart locks / security | King-Sodium Series 5 460mAh | Discharges at −50°C, rechargeable from 0V | ok |
| Remote controls / toys | King-Sodium Series 5 460mAh | Drop-in AA standard size | ok |
| Telecom base station backup | KS-Telecom 48V/600Ah | Lead-acid replacement, works at −40°C | ok |
| C&I peak shaving | KS-C&I 215kWh/100kW | 1–4 cabinets in parallel, 4–5 year payback | ok |
| On-site PV-storage | KS-1.7MWh + EMS | 2h configuration, parallel expansion | info |
| Residential self-consumption | KS-Home 10kWh/5kW | Wall-mounted / floor-standing | ok |
| Grid-side peak regulation | 120420-1200 cell | Utility container, custom integration required | info |
| Power for extreme cold | 120420-1200 cell | −40°C cold start verified | ok |
| Heavy-truck battery swapping | 120420-2500 cell | High per-cell capacity, fewer in series | warn |
| Construction machinery start-stop | 120420-600 cell | 1,000A pulse discharge | warn |
The above are standard products. If your application has special requirements for capacity, size, voltage platform or communication protocol, King-Sodium supports cell-level and system-level custom development.
Tell us your application and purchase volume, and we'll provide selection advice, a full technical pack and sample shipping.