Product portfolio: from one cell to a full storage plant

One polyanion + hard carbon system, split into three product lines by capacity, rate capability and cost, covering consumer electronics, traction and storage. Full specifications and selection rationale follow.

3product lines
280–2500Ah cell capacity range
−50 ~ +60°C operating range
4 system formats
King-Sodium Series 5Large-format cylindrical cellKS energy storage systemSelection decision table
PRODUCT 01

King-Sodium Series 5 — a battery unafraid of the cold

AA standard size, 3.0V, 460mAh. A drop-in replacement for equivalent lithium and alkaline cells, pushing the operating temperature floor down another 30 degrees.

King-Sodium Series 5 · Full datasheet summary NaMao-5 / AA 14500
Product modelKing-Sodium Series 5 (AA / 14500)
Nominal voltage / capacity3.0 V / 460 mAh @0.2C
Nominal energy1.5 Wh
Dimensionsφ14.0 × 50.0 mm (AA standard)
Weight≈ 21 g
Charge cut-off voltage4.0 V
Discharge cut-off voltage2.0 V
Max continuous discharge current2C (920 mA)
Peak pulse discharge1,000 A (millisecond class)
Low-temperature discharge≥80% capacity retention at −50°C
High-temperature dischargeOperates at +60°C
Charge temperature range−20℃ ~ +55℃
Cycle life≥800 cycles @70% retention
Self-discharge rate≤3% / month @25°C
Over-discharge recoveryCharges normally after 0V deep discharge
Housing materialNickel-plated steel / aluminium-laminate optional
Safety testsAll 12 passed (nail penetration, crush, thermal box)
Certification statusSGS CGE20251100120081 / UN 38.3 / RoHS / REACH
MOQ5,000 pcs
Standard lead time7 days in stock / 25 days custom

Temperature vs capacity retention

+60℃96%
+25°C (baseline)100%
0℃96%
−20℃92%
−30℃87%
−40℃83%
−50℃80%

Test conditions: 0.5C discharge to 2.0V, with 25°C capacity as the 100% baseline.

Cycle degradation curve

100 cycles99.2%
300 cycles96.4%
500 cycles91.3%
800 cycles84.0%
1,000 cycles78.5%

Test conditions: 1C charge / 1C discharge, 25°C, 100% DOD.

What 0V rechargeability means

In conventional lithium cells, over-discharge to 0V dissolves the copper anode current collector and forms dendrites on recharge, causing internal short circuits. King-Sodium Series 5 uses an aluminium collector and a matched system, so it recovers safely after over-discharge. For long-duration low-current standby devices such as locks and smoke detectors, this sharply cuts after-sales write-offs.

Target applications

Who King-Sodium Series 5 is for

Smart locks / access control

For long standby and cold environments, 0V rechargeability removes over-discharge write-offs.

Smoke & security sensors

Over 12 years of standby, with self-discharge as low as 3%/month.

Remote controls / toys

Drop-in AA standard size, no lithium or cobalt — cleaner by design.

Lighting / emergency power

Reliable discharge outdoors at −40°C, no fire at high temperature.

PRODUCT 02

120420 large cylindrical — engineering cost into the structure

The φ120 × 420mm large cylindrical format starts at 280Ah and reaches 2,500Ah per cell: fewer case parts, a shorter electron path and a clearer venting direction.

120420 series · Cell-level specifications 120420 SERIES
Series model120420 (φ120 × 420 mm)
Capacity tiers280 / 600 / 1200 / 2500 Ah
Nominal voltage3.0 V
Energy range0.84 kWh (280Ah) ~ 7.5 kWh (2,500Ah)
Cathode systemPolyanion (phosphate framework)
Anode systemBiomass hard carbon
Charge cut-off voltage4.0 V
Discharge cut-off voltage1.8 V
Max continuous discharge1C
Peak pulse discharge1000 A
Operating temperature · discharge−40℃ ~ +60℃
Operating temperature · charge−20℃ ~ +55℃
Cycle life≥6,000 cycles @80% DOD (storage duty)
Thermal runaway onset≥325°C (nail penetration)
Structural featuresFull-tab / bottom collector / axial venting
Case materialAluminium alloy (nickel-plated steel optional)
Volumetric utilisation≥92%
Pack efficiency≥88%
Capacity consistencywithin ±2%
Certification statusUL 1973 / UL 9540A / IEC 62619 / UN 38.3

Capacity tiers

0AhBaseline / C&I storage
0AhUtility storage / PV-storage
0AhGrid-side peak regulation
0AhHeavy trucks / marine

Structural advantage vs prismatic aluminium

Case & structural part usage−22%
Average electron path length−40%
Thermal consistencyMarked improvement
Module assembly steps−30%

On the engineering trade-offs of large cylindrical

Large cylindrical cells are not cost-free: the higher the per-cell capacity, the stricter the demands on BMS sampling accuracy and temperature uniformity; a larger diameter raises the precision required of winding equipment and electrode alignment. King-Sodium has completed full process validation on the 120420 platform and supplies module-level thermal simulation boundary conditions.

No lithium, cobalt or nickel

Raw materials avoid lithium, cobalt and nickel — elements exposed to geopolitical and price volatility — giving supply-chain stability well above NMC systems.

Intrinsic safety boundary

Polyanion cathodes decompose at a higher temperature than layered oxides; combined with a hard carbon anode, they neither ignite nor explode under nail penetration, with thermal runaway onset ≥325°C.

Cost over long cycling

6,000 cycles @80% DOD means over 8 years of theoretical service at two cycles a day, with a levelised cost below lead-acid and lithium options.

PRODUCT 03

KS Series storage systems — delivered by scenario, not by spec sheet

Four system formats span everything from 10kWh residential to 1.7MWh containers, all managed by our in-house EMS with multi-unit parallel operation and cloud-based strategy dispatch.

KS-1.7MWh

Containerised utility storage

0MWhCapacity per container
0kWRated power

720V DC side, 2-hour configuration, 20-ft standard sea container. Scalable in parallel to hundred-MWh plants.

20-ft standard containerIn mass production

KS-C&I

C&I storage cabinet

0kWhCapacity per cabinet
0kWRated power

Dual peak-valley arbitrage and demand management, 1–4 cabinets in parallel, integrated with the park EMS.

Floor-standing / outdoor cabinetIn mass production

KS-Home

Residential storage system

0kWhCapacity per unit
0kWInverter power

Wall-mounted and floor-standing formats, paired with residential PV for self-consumption, peak-valley arbitrage and backup.

Wall-mounted / floor-standingIn mass production

KS-Telecom

Telecom base station backup

0VStandard voltage
0AhCapacity per string

A drop-in lead-acid replacement: normal float charge and discharge in outdoor cabinets at −40°C, with over 3× the cycle life.

19-inch standard rackIn mass production

KS-1.7MWh system specifications

KS-1.7MWh · System-level specifications KC-1700-720-800
Rated DC-side voltage720 V
Rated capacity per container1.7 MWh
Rated power800 kW
Rated charge/discharge duration2 h
Cell configuration120420-600 modular series
Cycle life≥6,000 cycles @80% DOD
System efficiency≥92% (incl. PCS and thermal control)
Operating temperature−30℃ ~ +55℃
Thermal managementLiquid cooling + zoned air ducts
IP ratingIP54 (IP55 optional)
Fire suppressionPack-level aerosol + cabinet-level perfluorohexanone
Communication interfaceModbus TCP / IEC 61850 / CAN
EMS functionsPeak-valley strategy / demand control / remote O&M
Standard size20-ft standard sea container
WarrantySystem 5 years / cell 8 years (extendable)

KS-C&I system specifications

KS-C&I · System-level specifications KC-215-100
Capacity per cabinet215 kWh
Rated power100 kW
DC voltage range600 – 900 V
Cell configuration120420-280 modular
Cycle life≥6,000 cycles @80% DOD
System efficiency≥90%
Operating temperature−20℃ ~ +50℃
Thermal managementLiquid cooling / air conditioning optional
IP ratingIP54 (outdoor cabinet)
Fire suppressionPack-level aerosol + smoke detection
Parallel capability1–4 cabinets in parallel (up to 860 kWh)
Communication interfaceModbus TCP / 4G gateway
InstallationFloor-standing / outdoor / in-container
Typical payback4–5 years (Jiangsu–Zhejiang peak-valley spread)
WarrantySystem 5 years / cell 8 years

On the payback calculation basis

The payback figures above assume a typical Jiangsu–Zhejiang C&I peak-valley spread (about RMB 0.75/kWh), one charge-discharge per day and 330 operating days a year. Actual payback depends on local tariff policy, load profile and grid-connection conditions; King-Sodium can produce a custom calculation for your project.

SELECTION

Selection decision table

Locate the recommended product quickly by application, temperature and capacity.

ApplicationsFeatured productsSelection notesMaturity
Smart locks / securityKing-Sodium Series 5 460mAhDischarges at −50°C, rechargeable from 0Vok
Remote controls / toysKing-Sodium Series 5 460mAhDrop-in AA standard sizeok
Telecom base station backupKS-Telecom 48V/600AhLead-acid replacement, works at −40°Cok
C&I peak shavingKS-C&I 215kWh/100kW1–4 cabinets in parallel, 4–5 year paybackok
On-site PV-storageKS-1.7MWh + EMS2h configuration, parallel expansioninfo
Residential self-consumptionKS-Home 10kWh/5kWWall-mounted / floor-standingok
Grid-side peak regulation120420-1200 cellUtility container, custom integration requiredinfo
Power for extreme cold120420-1200 cell−40°C cold start verifiedok
Heavy-truck battery swapping120420-2500 cellHigh per-cell capacity, fewer in serieswarn
Construction machinery start-stop120420-600 cell1,000A pulse dischargewarn

Three questions

  • What is the low-temperature limit?If the equipment must run below −20°C, sodium-ion is almost the only option needing no heating pad.
  • How many cycles per day?Above two cycles a day, cycle life drives lifecycle cost directly, where sodium-ion leads clearly.
  • Upfront cost or levelised cost?If upfront investment dominates, choose sodium-ion; for maximum energy density, lithium still deserves evaluation.

Need a custom build?

The above are standard products. If your application has special requirements for capacity, size, voltage platform or communication protocol, King-Sodium supports cell-level and system-level custom development.

Need the full datasheet, test report or samples?

Tell us your application and purchase volume, and we'll provide selection advice, a full technical pack and sample shipping.