Phase I of the Luoding 10GWh sodium battery plant reaches full capacity
Phase I lines passed full-load validation with yield steady at 99%; the large-format 120420 series has entered volume delivery.
King-Sodium focuses on the R&D, manufacturing and system integration of polyanion sodium-ion batteries. From AA-size consumer cells to 2,500Ah large-format cells and MWh-scale storage systems, we turn wide temperature range, intrinsic safety and unrestricted resources into deliverable products.
One polyanion + hard carbon system, tiered by energy density, rate capability and cost, covering consumer, traction and storage.
AA / 14500 standard size · 3.0V · 460mAh · 1.5Wh
For consumer electronics, smart locks, remote controls, electric toys and cold-climate backup power. In the standard 14500 size (φ14 × 50mm) it directly replaces equivalent lithium and alkaline designs, still discharging normally at −50°C and recovering from deep discharge to 0V, avoiding over-discharge write-offs.
Test conditions: 0.5C discharge to 2.0V; nominal capacity at 25°C taken as 100%.
| Product model | King-Sodium Series 5 (AA / 14500) |
| Nominal voltage | 3.0 V |
| Nominal capacity | 460 mAh @0.2C |
| Nominal energy | 1.5 Wh |
| Dimensions | φ14.0 × 50.0 mm |
| Weight | ≈ 21 g |
| Charge cut-off voltage | 4.0 V |
| Discharge cut-off voltage | 2.0 V |
| Max continuous discharge | 2C (920 mA) |
| Peak pulse discharge | 1,000 A (millisecond class) |
| Operating temperature · discharge | −50℃ ~ +60℃ |
| Operating temperature · charge | −20℃ ~ +55℃ |
| Cycle life | ≥800 cycles @70% retention |
| Self-discharge rate | ≤3% / month @25°C |
King-Sodium Series 5 resumes normal charging after over-discharge to 0V, avoiding the internal short caused by copper dissolution — markedly better than conventional lithium designs in storage, transport vibration and series mismatch.
φ120 × 420 mm · from 280Ah · up to 2,500Ah per cell
Large cylindrical construction is the natural answer to sodium-ion cost and safety. A larger winding diameter means fewer case and connector parts, a shorter average electron path and more uniform heat dissipation. Using 280Ah as the baseline, King-Sodium's 120420 series pushes per-cell capacity to 2,500Ah through electrode formulation and stacking-density optimisation, giving utility storage and heavy-truck swapping fewer series links and higher system reliability.
| Model | Capacity | Typical applications | |
|---|---|---|---|
| 120420-280 | 280 Ah | C&I storage / telecom backup | ok |
| 120420-600 | 600 Ah | Utility container / PV-storage | info |
| 120420-1200 | 1200 Ah | Grid-side peak regulation / shared storage | info |
| 120420-2500 | 2500 Ah | Heavy-truck swapping / marine | accent |
Versus prismatic aluminium cases, large cylindrical cells use about 22% fewer case and structural parts at equal capacity.
Containerised utility-scale storage
720V / 800kW / 2h configuration, scalable in parallel to hundred-MWh plants.
C&I storage cabinet
Peak-valley arbitrage plus demand management, with parallel cabinets and cloud EMS dispatch.
Residential storage
Wall-mounted or floor-standing, paired with PV for self-consumption and emergency backup.
Telecom backup
A drop-in lead-acid replacement: normal float charge and discharge at −40°C in outdoor cabinets.
| Rated DC-side voltage | 720 V |
| Rated capacity per container | 1.7 MWh |
| Rated power | 800 kW |
| Rated charge/discharge duration | 2 h |
| Cell configuration | 120420-600 × modular series |
| Cycle life | ≥6,000 cycles @80% DOD |
| System efficiency | ≥92% (incl. PCS and thermal control) |
| Operating temperature | −30°C to +55°C (liquid-cooled) |
| IP rating | IP54 (IP55 optional) |
| Fire suppression | Pack-level aerosol + cabinet-level perfluorohexanone |
| Communication interface | Modbus TCP / IEC 61850 / CAN |
| Standard size | 20-ft standard sea container |
| Applications | Featured products | Key notes |
|---|---|---|
| Telecom base station backup | KS-Telecom 48V/600Ah | Lead-acid replacement, works at −40°C |
| C&I peak shaving | KS-C&I 215kWh/100kW | 1–4 cabinets in parallel |
| On-site PV-storage | KS-1.7MWh + EMS | Mainly 2h configuration |
| Residential self-consumption | KS-Home 10kWh/5kW | Wall-mounted / floor-standing |
| Power for extreme cold | 120420-1200 cell | −40°C cold start |
| Heavy-truck battery swapping | 120420-2500 cell | High per-cell capacity, fewer in series |
The first rule of selection isn't energy density — it's how much usable energy remains under your real temperature profile and discharge rate.
King-Sodium application engineering teamThe gap between sodium-ion and lithium-ion is not just the periodic table: it lies in cathode crystal structure, anode sodium-storage mechanism and the whole line's process window. King-Sodium has engineered all three.
Polyanion cathode (NASICON-like framework) with a hard carbon anode. The phosphate framework provides structural stability and the lattice distorts little as sodium inserts and extracts, giving better cycle life and thermal stability than layered oxides.
Full-tab large cylindrical cells with a bottom current collector. Shortening the current path lowers resistance, enabling 1,000A-class pulses while concentrating heat on the liquid-coolable case surface.
Luoding controls cost through full-line automation and low-energy drying. Sodium batteries don't need lithium's ultra-low-humidity environment, so energy use and depreciation both fall.
| Generation | Cathode system | Energy density | Cycle life | Cost target | Status |
|---|---|---|---|---|---|
| G1 | Polyanion (phosphate) | ≥ 110 Wh/kg | 3,000 cycles | ≤ RMB 0.35/Wh | Mass production |
| G2 | Polyanion enhanced | ≥ 140 Wh/kg | 6,000 cycles | ≤ RMB 0.28/Wh | Small batch |
| G3 | Hybrid system / doping | ≥ 175 Wh/kg | 8,000 cycles | ≤ RMB 0.23/Wh | Pilot line |
| G4 | Sodium solid-liquid hybrid | ≥ 220 Wh/kg | 10,000 cycles | ≤ RMB 0.20/Wh | Pre-research |
Source: King-Sodium Research Institute internal test reports; conditions per lab method LAB-M-2025-03.
Not every scenario suits sodium-ion. We focus on where temperature, cost or resources are a real constraint.
Hundreds of thousands of outdoor base stations still run on lead-acid. Sodium-ion drops straight in, works at −40°C and lasts over 3× longer.
DeployedAs peak-valley spreads widen, storage cabinet payback shortens to 4–5 years. Lower upfront cost directly improves IRR.
DeployedNo lithium or cobalt, and no fire at high temperature. In hot, humid markets such as Southeast Asia and Africa, safety is a harder requirement than energy density.
ExpandingDischarging at −50°C means outdoor equipment in northeast China, Inner Mongolia and Northern Europe no longer needs heating pads or dual-power designs.
DeployedThe large cylindrical cell's 1,000A pulse capability suits heavy-load start-stop duty, and high per-cell capacity reduces series connections in swap mode.
VerifiedFor long-standby devices such as smart locks, smoke detectors and emergency lighting, 0V rechargeability removes the after-sales cost of over-discharge write-offs.
ExpandingGlobal sodium-ion shipments are expected to grow from 13GWh in 2025 to 583GWh in 2030, with storage and low-speed traction driving the increase.
| Comparison basis | King-Sodium | Li-ion | Verdict |
|---|---|---|---|
| Material cost | RMB 0.23/Wh | RMB 0.38/Wh | Sodium-ion wins |
| Low-temperature performance | Discharges at −50°C | Sharp capacity drop at −20°C | Sodium-ion wins |
| Safety | Intrinsic safety, no fire on nail penetration | Higher thermal runaway risk | Sodium-ion wins |
| Cycle life | 3,000–6,000 cycles | 3,000–8,000 cycles | Mixed |
| Energy density | 110–175 Wh/kg | 160–260 Wh/kg | Li-ion wins |
| Resource constraints | No Li/Co/Ni, ample resources | Li/Co supply geopolitically constrained | Sodium-ion wins |
In the near term sodium-ion cannot match NMC lithium on energy density and is no substitute in long-range passenger cars. But in storage, backup, extreme-cold traction and consumer scenarios its cost, safety and wide-temperature advantages are genuinely competitive — and King-Sodium is built around exactly those scenarios.
Phase I lines passed full-load validation with yield steady at 99%; the large-format 120420 series has entered volume delivery.
All 12 safety tests passed, report CGE20251100120081, with UN 38.3 transport certification completed in parallel.
Covering South, East and Northwest China, the first KS-C&I 215kWh storage cabinets are delivered and grid-commissioned.
A systematic account of King-Sodium's engineering practice and test data across cathode modification, hard carbon anodes and wide-temperature electrolytes.
From materials to systems, from line to service — four layers of verifiable delivery capability.
Formulas, structural design and process parameters are all developed in-house, with no external licensing.
Luoding plant is planned at 10GWh; Phase I is in production with reliable delivery capability.
Full traceability from incoming materials to finished goods — batch consistency is the core of storage.
We don't just sell cells — we handle selection, system design, protocol integration and after-sales.
Share your temperature profile, load characteristics and site conditions; our application engineering team returns selection advice and a lifecycle cost estimate within 3 working days.